Db25 Pin Assignment

RS232 Connector Pin Assignment
RS232 Cable Information
DB 9 and DB 25 Connection

The original pin layout for RS232 was developed for a 25 pins D sub connector.  In this pin-out provisions were made for a secondary communication channel. In practice, only one communication channel with accompanying handshaking is present. For that reason the smaller 9 pin version is more commonly used today.

The diagrams show the signals common to both connector types in black. The signals only present on the larger connector are shown in red.

Note: The protective ground is assigned to a pin at the large connector, in DB9 version protective ground connector to encloser.

For the DEC modified modular jack. Although is differential (the receive and transmit have their own floating ground level) still possible to connect RS232 compatible devices with this interface.

RS232 DB 9 Pin Assignment

RS232 DB 25 Pin Assignment



DB9 to DB25 converter
The original pin layout for RS232 was developed for a 25 pins D sub connector. From IBM-AT machine popular 9 pins connectors are commonly used. RS232 DB9 to DB25 converter cable support mixed applications for 9 to 25 pins.

RS232 DB9 to DB25 converter


RS232 loop-back test plug
The following connectors can be used to self-test a serial port on your computer. The data and handshake lines have been linked. In this way all data will be sent back immediately. The PC controls its own handshaking.
Download test software from: www.pccompci.com

RS232 loop-back test plug for PCCOM Diagnostics
             
      


RS232 null modem cables

The using a null modem cable is easiest way to connect two PC's.
For simple connections, a three line cable connecting the signal ground and receive and transmit lines is sufficient.
Depending of the software used, some sort of handshaking may however be necessary. Use the selection table to find the right cable for each purpose.

For Microsoft Windows use direct cable connection, the null modem cable with loop back handshaking.

Null modem cables with handshaking can be defined in numerous ways, with loop back handshaking to each PC, or complete handshaking between the two systems. The most common cable types are shown here.

Simple null modem without handshaking


Null modem with loop back handshaking


Null modem with partial handshaking


Null modem with full handshaking


Choose your null modem cable
Use
Simple cable Without Handshaking
Cable with Loop back Handshaking
Cable with Partial Handshaking
Cable with Full Handshaking
Software flow control only
xxx
x
x
x
DTE/DCE compatible hardware flow control at low speeds
-
xxx
xx
-
DTE/DCE compatible hardware flow control at high speeds-
+
xxx
-
High speed communication using special software
-
-
xx
xxx
Note :
xxx
Recommended cable
x
Good alternative
x
Works, but not recommended
-
Does not work

RS232 printer cable
When a serial printer is connected to a PC, the handshaking is not symmetrical any more. In that case a cable is used where some handshaking lines at the PC side are looped back. On the printer side only the data lines and one handshaking line are used.

RS232 monitor cable
It is not difficult to monitor the serial communication between two devices with a PC. To do this you need the monitor cable, which is displayed in the next picture. Two sockets are connected straight through. The PC is connected to the third one.

This monitor cable taps communication from both sides. This means that if the two devices happen to talk simultaneously, the monitored information will be garbage. In most circumstances communication software works half duplex, in which case this problem does not exist.


SPECIFICATIONS
RS232
RS422
RS485
Mode of Operation
SINGLE-ENDED
DIFFERENTIAL
DIFFERENTIAL
Total Number of Drivers and Receivers on One Line (One driver active at a time for RS485 networks)
1 DRIVER
1 RECVR
1 DRIVER
10 RECVR
32 DRIVER
32 RECVR
Maximun Cable Length
50 FT.
4000 FT.
4000FT.
Maximum Data Rate (40ft. -4000ft. for RS422/RS485)
20Kb/s
10Mb/s -100Kb/s
10Mb/s -100Kb/s
Maximun Driver Output Vlotage
+/-25V
-0.25V to +6V
-7V to +12V
Driver Output Signal Level (Loaded Min.)
Loaded
+/-5V to +/-15V
+/-2.0V
+/-1.5V
Driver Output Signal Level (Unloaded Max.)Unloaded
+/-25V
+/-6V
+/-6V
Driver Load Impedance (Ohms)
3k to 7k
100
54
Max. Driver Current in High Z State
Power On
N/A
N/A
+/-100uA
Max. Driver Current in High Z State
Power Off
+/-6mA @ +/-2V
+/-100uA
+/-100uA
Slew Rate (Max.)
30V/uSN/AN/A
Receiver Input Voltage Range
+/-15V
-10V to +10V
-7V to +12V
Receiver Input Sensitivity
+/-3V
+/-200mV
+/-200mV
Receiver Input Resistance (Ohms), (1 Standard Load for RS485)
3K to 7K
4K min.
>=12K

RS 232 EIA, EDC and EMI Bulk Data Cable
Standare EIA, Extended Distance Low Capacitance and EMI/RFI Double Shielded Data Cable.



RS232 connections, and wiring up serial ports

Pin 1Protective Ground

Custom Electronics

Do you need - Networked Serial
Electronics? Metering, Controllers,
Callpoints, Fire panels, access
control, lighting, robotics
--We design and build--
Call us now! (02)9925 0325

Pin 2Transmit Data
Pin 3Received Data
Pin 4Request To Send
Pin 5Clear To Send
Pin 6Data Set Ready
Pin 7Signal Ground
Pin 8Received Line Signal Detector
(Data Carrier Detect)
Pin 20Data Terminal Ready
Pin 22Ring Indicator

The connector on the PC has male pins, therefore the mating
cable needs to terminate in a DB25/F (Female pin) connector.


Pin 1Received Line Signal Detector
(Data Carrier Detect)
Pin 2Received Data
Pin 3Transmit Data
Pin 4Data Terminal Ready
Pin 5Signal Ground
Pin 6Data Set Ready
Pin 7Request To Send
Pin 8Clear To Send
Pin 9Ring Indicator

The connector on the PC has male pins, therefore the mating
cable needs to terminate in a DE9/F (Female pin) connector.
[Some people call this a DB9... DE9 is the real name, however]

Wiring up something nice and simple, for instance a plain old "dumb terminal", is just a matter of connecting Tx, Rx and Ground, right?

Usually Not. While the normal PC hardware might well run with just Tx, Rx and Ground connected, most driver software will wait forever for one of the handshaking lines to go to the correct level. Depending on the signal state it might sometimes work, other times it might not. The reliable solution is to loop back the handshake lines if they are not used. We specifically chose to use the Personal Computer (PC) as the frame of reference for the signals on this page. RS232 predates the PC, but even with EIA-574 and the later TIA-232-F the definitions still use DTE (Data terminal equipment - such as a PC or equivalent) and DCE (Data circuit-terminating equipment - such as a modem or 'dumb terminal' or any other device) as the frame of reference. We are trying to flatten the learning curve: On this page "PC" is used in place of the technical term "DTE".


Handshake looping a PC serial connector

When the lines are handshake looped, the RTS output from the PC immediately activates the CTS input - so the PC effectively controls its own handshaking... which leads in to what each of the pins on the RS232 connector (or EIA574 in the case of the DE9) actually does - we have a proper description of all the pins further down this page.



RS232 DE9 PC Loopback test plug Build it yourself using the photo to the right as a guide - or if you prefer we will do it for you:
 
$18 + shipping
The PC loopback plug is a useful diagnostic tool. The loopback plug connects
serial inputs to serial outputs so that the port may be tested. There is more
than one way to wire up a loopback plug - but this is the most common.


RS232 DB25 PC Loopback test plug

Connecting together two serial devices involves connecting the Rx of one device to the Tx of the other, and vice versa. The diagram below indicates how you would go about connecting two PC's together, without handshaking.


Connecting two PCs together using RS232, without handshaking

When Handshaking is required, generally RTS of one device connects to CTS of the other, and vice versa, and also DSR of one device connects to DTR of the other device, and vice versa. The particular requirements for different equipment may vary.


Connecting two PCs together using RS232, with handshaking

Using a Breakout box or LED box to work out cabling

If you have problem with RS232 cabling, your best "emergency" tool may be a breakout box (sometimes called an LED box). The normal units only come in the DB25 size, but with a couple of DB9 to DB25 adaptors, they can be used with DB9 cables as well. The units have an LED for each signal line in the cable, and the LED lights green or red dependent on the signal state. Our D9 Breakout box is a little more sophisticated - it also allows you to disconnect certain lines in the cable, and to loop signals to their opposite number - good for trying new cable wiring possibilities.

The first thing to remember, is that there is a good chance the two devices you are trying together will actually work if you can get the cable correct. If you have some other way to actually prove this - for instance by trying each of the devices on another system - do it.

Given a hypothetical example - for instance connecting a standard PC with a DE9M to an CNC industrial turret punch, also with a DE9M, the first thing I would try and do is get a cable that I think would work. In this instance, I would either purchase or build a null-modem cable (DB9F to DB9F) - actually, I would copy the last example, basically the cable used to connect two PCs together with handshaking.

Given the cable that I believe will work, connect the cable, LED box and two devices all together. Before powering on both devices, unplug just one of them. Power the devices on and make a note of which LEDs are lit. Then unplug the connected device and plug in the disconnected one, without rearranging the cabling otherwise. Again make a note of which LEDs are lit. If any single LED is lit by both of the devices, then there is an output conflict, and the cable wiring is incorrect. By this, I mean that one line in the cable has an output driving it from both ends - and this is not correct for RS232 - so that means that the cable wiring is not correct for the devices. Pay particular attention to Tx and Rx.

To continue with the example above, if I saw that two ends were driving the same lines, I would assume the null modem cable was not correct, and I would try a one-for-one (or "straight-thru" DE9F-DE9M cable) with a gender changer (DE9F-DE9F in this instance) instead.

If each end drives its own set of LEDs, connect the two ends together. In normal situations, you should see all the LEDs light up - but there are some devices which will not light up all the LEDs. Having said that, if one of the devices is a PC and any LED except RI (Ring indicator) is not lit up, the cable will probably not work.

Normally, other cabling problems will involve handshake lines. An LED box will be an invaluable guide, but there is no trivial test to determine the solution. An LED Box will also show the lines as they change state, although with the D25 models it is usually quite hard to see the serial communications themselves unless the comms are continuous, or at a low baud rate (9600 baud or lower is usually visible). Our D9 Model has superbright LEDs on the data lines, so seeing brief packets is not a problem.

If you have difficulty in obtaining gender changers, null-modem / straight-thru cables, D25/D9 converters (etc) email us, we carry everything you could need to test and debug serial comms, and we can quote by return. Our main business is designing industrial electronics - much of it serially controlled or networked.


Pin 1DCDData Carrier Detect This is one of two unpaired handshake lines. Its original function was mainly for modem connections - it specified when the modem was actively receiving carrier - the base modulation on which the data frequencies were superimposed - and thus was likely to be able to link to remote end. There was not much point in trying to send data until carrier was established.
Pin 2RxDReceived Data Serial data being sent by the connected equipment to the pc. (ie, this is The data the PC receives) Normally the signal is between -3V to -12V when no data is being sent, and pulses up to +3V...+12V to send the data
Pin 3TxDTransmit Data Serial data being sent by the PC. Signal is normally -5V and pulses to +5V to send the data
Pin 4DTRData Terminal ReadyPC End is ready. This signal normally goes active (+5V) at the start of communications - perhaps when appropriate software starts, or power up is complete - and it normally remains active for the whole "session". When it goes inactive, if forces the end of the communication session. Modems hang up when this signal goes inactive. The matching signal from the other end is DSR - this is active when the other equipment is also ready to operate.
Pin 5GNDSignal Ground Ground - both devices are connected by this ground signal. Attention must be paid to grounding of the two devices to ensure that the two ends do not have a significant voltage difference.
Pin 6DSRData Set Ready Acknowledgement to the PC that the other equipment is ready for operation. Goes active +3...+12V when ready. If unused, it is often tied to DTR, so when the computer indicates that it is ready for communications by asserting DTR, DSR is similarly asserted to encourage the PC to get things underway
Pin 7RTSRequest To Send PC Requests to send data. The PC sends this signal active (+5V) to tell the other device it wants to send data - and then the other end responds by sending CTS active (= +3...+12V "Yes, you are Clear to Send").
Some equipment uses the RTS signal differently, as a Ready to Receive signal. In this situation, the PC-end sends RTR active to say the PC is ready to receive, while the remote-end still sends CTS active to say the remote-end is ready to receive.
Pin 8CTSClear To Send Response signal input by PC: PC asks to send with RTS, then waits for the CTS response before beginning. Part way through a transmission, the other device may send CTS inactive this is interpreted as "stop sending for now".
Pin 9RI Ring Indicator This is the second of two unpaired handshake lines. Its original function was (also) mainly for modem connections - it goes active when the telephone is ringing. The signal is input to the PC and is normally -3V to -12V when idle, and +3 to +12V when the telephone is ringing. This signal is rarely used today.

RS232 defines voltages as a nominal +/-12V, current limited to about 12ma. However, most equipment will work with anything from +/-3V and up. Some equipment omits the negative, signals with +5V/0V ...and mostly works. Some drivers use reduced +/-5V voltages to save power, and these work with (our estimate) 99% of equipment.
The small USB to serial converters used with a PC usually output +/-5V levels - but may also output no voltage at all when the software driver for the serial port is not active. They receive any input +/-3V...+/-12V.


We left this unweildy description for last, because while it is good
to know what everything does, it is easier to just try a loopback first.

Using a 'T' plug and a PC to monitor comms

The gadget below is a quick half hour project that is really great for monitoring RS232 Comms using a PC. The circuit is really not that hard to build - the parts can be purchased from Tandy / Radioshack / Dicksmith / Jaycar / Maplin / Farnell - but if you want to buy it ready made off us, just use the button below.


How to monitor RS232 Comms between two devices
 
$46 + shipping

There are three sockets on the T-Spy gadget. Two of them are connected straight through - plug them in series with the devices you wish to monitor - and the third goes off to a seperate PC for monitoring the communications.

The monitoring PC "Sees" on its serial port both sides of the serial conversation - that is it receives what is sent by the target PC and also what is sent by target peripheral. This can be a positive advantage, because the serial conversation can be observed as it progresses between the two devices. Some serial protocols, however, talk "full duplex" meaning that one end can start transmitting while it is still receiving from its peer. This unit cannot monitor full duplex Comms - the comms will be corrupted, gobble-dee-gook will be seen where the two transmissions overlap. The two sides of the conversation are wire-AND'ed, so Space or 0 overrides Mark or 1. But in addition the two sources are asynchronous, so reconstruction of a simultaneous conversation is not realistic.

This device is surprisingly successful in operation, and works to successfully record RS232 protocols for many different installs - mostly because many supposedly full duplex installations still talk half duplex in any case, because that is the sensible way to write the software. All in all, Not bad for one diode and a resistor...